HeatWave
Specifications
|
Model |
Model
H75
|
Model
H100 |
Model
H125 (All Options) |
Model
125 -3 |
|
Effiency
at 80'F, 80RH
BTU rating per Hour:
Heating/Cooling
Killowat Output
|
64,000
|
90,000
5.2
|
118,000/82,600
5.2
|
118,000
5.2
|
|
Electrical
Minimum Circuit (AMPS)
Maximum Fuse Size
|
208-230V
(1phase)
24
30
|
208-230V
(1phase)
37
40
|
208-230V
(1 phase)
27
40
|
208-230V
(3phase)
27.8
30
|
|
Water Flow
Minimum/Maximum
|
16-70
|
20-70
gpm
|
20-70
gpm
|
20-70
gpm
|
Physical
Shipping Weight
Size(lenghtxWidthxHeight) |
276
lbs
|
380
lbs
36x32x42.5"
|
380
lbs
36x32x42.5"
|
380
lbs
36x32x42.5"
|
| Warranty:
10 Year compressor warranty and a 5 year parts & labor to the
original owner |
|